R-5461-CM-GS Calcined Mica Tape uses calcined muscovite mica paper with alkali-free glass fibre cloth on one side, bonded with silicone resin. Thickness 0.10–0.14 mm, width 4.5–1000 mm, roll length 500/1000/2000 m, standard cores 52/54/76/120 mm. It does not break down for 90 minutes at 850–900 ℃ and 600–1000 V, meeting BS 6387 and IEC 60331. Contact Kaxite for a free sample and factory quotation.
R-5461-CM · Calcined Muscovite

R-5461-CM-GS Calcined Mica Tape for Fire-Resistant Cable

Calcined mica tape is built on calcined muscovite mica paper, reinforced on one side with alkali-free glass fibre cloth and bonded with silicone resin. The single-sided glass cloth — widely specified as a glass backed mica tape — carries the tensile load, so the mica layer stays intact at high wrapping speed. After high-temperature baking, drying and slitting, the tape is wrapped between the conductor core and the outer sheath of fire-resistant cables, where it must keep the circuit alive while the fire is still burning.

Compared with phlogopite and synthetic grades, the calcined type is the workhorse for volume cable production: it reaches the same BS 6387 / IEC 60331 fire window at a lower mica cost per metre, which is why it is the most widely ordered R-5461 variant for multi-storey buildings, tunnels and power stations.

0.10–0.14 mmStandard thickness range
4.5–1000 mmSlitting width
500 / 1000 / 2000 mRoll length options
90 min @ 850–900 ℃No breakdown, 600–1000 V
R-5461-CM-GS calcined mica tape roll with glass fibre reinforcement for fire-resistant cable insulation

What "Calcined" Changes on the Line

Calcination drives off crystal water and volatile matter from the raw muscovite, leaving a thermally stable mica paper that does not blister or delaminate when the fire test ramps to 900 ℃.

The single-sided glass cloth carries the tensile load, so the mica layer stays intact while the tape is pulled around tight conductor cores at high speed. Surface is smooth, flat, dry and non-adhesive.

R-5461-CM-GS is the standard designation for this construction: calcined mica paper, glass on single side.

01

Calcined mica paper as the base

High-purity muscovite is calcined to remove crystal water, then formed into a continuous paper. The result keeps its dielectric strength at 850–900 ℃ for the full 90-minute fire window.

02

Alkali-free glass cloth on one side

Glass fibre cloth gives the tape its tensile strength and bending flexibility, so it survives high-speed wrapping around conductor cores without cracking or tearing.

03

Silicone resin bonding

The mica paper and glass cloth are bonded with silicone resin, then baked at high temperature. The bond resists acid and alkali, ages slowly and releases no toxic gas when heated.

04

Drying and precision slitting

The cured web is dried and slit from 4.5 mm up to 1000 mm, then wound on 52 mm, 54 mm, 76 mm or 120 mm cores to match the customer's taping equipment.

Type

R-5461-CM-GS Grade

RRongtai product serial prefix — used across the whole R-5461 fire-resistant mica tape family.
5461Product serial number for the fire-resistant cable mica tape series.
CMCalcined mica — the base paper is calcined muscovite, not phlogopite or synthetic mica.
GSGlass on single side — alkali-free glass fibre cloth reinforcement on one face.

Note: R-5461-CM-GS is the standard calcined grade. Other mica paper types and reinforcement combinations (GD, GFD, FS, and phlogopite / synthetic variants) are available under the same R-5461 family — see the Mica Tape in Spool page for the full code list.

Spec

Performance Parameters — R-5461-CM-GS

Swipe horizontally to see all columns →

Item Unit 0.10 mm 0.12 mm 0.14 mm
Appearance — No alien material, no split, no scar or hole, no broken fold
Length m 500 / 1000 / 2000
Thickness mm 0.10 ± 0.015 0.12 ± 0.015 0.14 ± 0.015
Weight of tape g/m² 129 ± 8 161 ± 10 173 ± 12
Mica content g/m² 80 ± 3 110 ± 5 120 ± 5
Binder content g/m² 21 ± 3 23 ± 3 25 ± 5
Breakdown voltage kV >1.2 >1.6 >1.8
Tensile strength N/15 mm >120
Fire grades ℃ BS 6387 / 850–900 ℃, IEC 60331

Standard cores: 52 mm, 54 mm, 76 mm, 120 mm. Custom widths and core sizes can be produced to your drawing.

Benefits

What the Tape Delivers

90′

90 minutes without breakdown

The R-5461-CM tape holds its insulation at 850–900 ℃ and 600–1000 V for the full 90-minute fire window, keeping emergency circuits live.

℃

High-temperature resistance

Calcined mica paper loses its crystal water before the tape is made, so there is no blistering, delamination or loss of dielectric strength during the fire test.

⚗

Stable chemistry

Excellent acid and alkali resistance with strong ageing resistance. In a dry, room-temperature store the tape keeps its properties for at least one year.

✓

Clean burn behaviour

No toxic components in the formulation and no toxic gas released at high temperature — important for tunnels, ships and enclosed public buildings.

N

Tensile strength above 120 N/15mm

Glass cloth reinforcement gives good bending flexibility and high tensile strength when wrapping wire and cable at high line speed.

═

Uniform surface

Smooth, flat, dry and non-adhesive. The tape does not self-stick on the roll and unwinds evenly, so wrapping tension does not drift.

Use

Typical Applications

Oil platforms Multi-storey buildings Power stations Industrial plants Tunnels Computer centres Aerospace centres Telecommunication centres Ships Military installations

Packaging & storage: supplied in cardboard boxes or wooden boxes. Keep in a dry environment at room temperature; storage period is at least 1 year.

FAQ

Buyer Questions

QWhat is the difference between calcined mica tape and phlogopite mica tape?

ABoth use mica paper as the base. Calcined mica paper is made from muscovite that has been calcined to remove crystal water, giving a stable and cost-effective base for volume fire-resistant cable production. Phlogopite mica paper is used where a longer or higher-temperature fire window is required. Choose calcined for cost, phlogopite for the most demanding fire tests.

QWhich thicknesses and roll lengths can I order for calcined mica tape?

AStandard thicknesses are 0.10 mm, 0.12 mm and 0.14 mm, all with ±0.015 mm tolerance. Slitting width runs from 4.5 mm to 1000 mm. Standard roll lengths are 500 m, 1000 m and 2000 m; for continuous high-speed wrapping, the same tape can be supplied on 50,000 m spools — see Mica Tape in Spool.

QWhich fire test standards does calcined mica tape meet?

ABS 6387 at 850 ℃–900 ℃ and IEC 60331. The tape does not break down for 90 minutes at 850–900 ℃ and 600–1000 V, matching the requirement most often written into fire-resistant cable specifications.

Factory direct · Free sample

Get a quotation for calcined mica tape

Tell us your thickness, width, roll length and target fire standard. Kaxite will confirm the R-5461-CM-GS specification, lead time and price for your cable line.

Hot Tags:
Send Inquiry
Contact Info
Leave us messages, we'll provide the best solution for you!
X
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies. Privacy Policy
RejectAccept